-
How to Erase Writing According to Recipes from the Arab World: Replication an...
Multi analytical dataset of erased mockup samples, supporting the publication: "How to Erase Writing According to Recipes from the Arab World: Replication and Analytical... -
X-Ray Fluorescence and Reflectography Data from Hamburg, Staats- und Universi...
XRF (Bruker M6 JetStream: 50kV, 600 µA, maps with 50 µm step and 100 ms per pixel) and reflectography (DinoLite AD4113T-I2V: x40 magnification, transmissive,... -
X-Ray Fluorescence and Reflectography Data from Vatican, Vatican Library Ms V...
XRF (Elio: 40kV, 80 µA, spot measurements of 90s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Vatican Library... -
X-Ray Fluorescence and Reflectography Data from Vatican, Vatican Library Ms R...
XRF (Elio: 40kV, 80 µA, spot measurements of 90s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Vatican Library... -
X-Ray Fluorescence and Reflectography Data from Vatican, Vatican Library Ms R...
XRF (Elio: 40kV, 80 µA, spot measurements of 90s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Vatican Library... -
X-Ray Fluorescence and Reflectography Data from Vatican, Vatican Library Ms V...
XRF (Elio: 40kV, 80 µA, spot measurements of 90s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Vatican Library... -
X-Ray Fluorescence and Reflectography Data from Hamburg, Staats- und Universi...
XRF (Bruker M6 JetStream: 50kV, 600 µA, maps with 70 to 200 µm steps and 40-50 ms per pixel) and reflectography (DinoLite AD4113T-I2V: x40 magnification, vis,... -
X-Ray Fluorescence and Reflectography Data from Berlin, Staatsbibliothek zu B...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
X-Ray Fluorescence and Reflectography Data from Dublin, Chester Beatty Librar...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks and pigments (for... -
X-ray Fluorescence and reflectography data of Ethiopian manuscript CHJN003
XRF (Artax: 50kV, 600 µA, linescans of 10 points of 50s each each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV... -
X-Ray Fluorescence and Reflectography Data from Forschungsbibliothek Gotha Ms...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
X-Ray Fluorescence and Reflectography Data from Berlin, Staatsbibliothek zu B...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
X-Ray Fluorescence and Reflectography Data from Milan, Ambrosian Library, Ms ...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Milan, Ambrosian... -
IMC Leeds 2022 workshop: Bridging the Borders: Fifty Shades of Black (Ink)
Bridging the Borders: Fifty Shades of Black (Ink) - A Workshop Medieval manuscripts are written with different black and brown ink types, which usually vary between the... -
X-Ray Fluorescence and Reflectography Data from Paris, Bibliothèque Nationale...
XRF (Elio: 40kV, 20 µA, spot measurements of 30-60s each), and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of pigments from miniatures of... -
X-Ray Fluorescence and Reflectography Data from Wolfenbüttel, Herzog August B...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 30s each) and reflectography (DinoLite: x50 magnification under vis, NIR and UV light) analysis of inks and pigments... -
X-Ray Fluorescence and Reflectography Data from Cambridge, Wren Library Ms B1...
XRF (Elio: 40kV, 100 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, x200 magnification for spots on... -
X-Ray Fluorescence and Reflectography Data from Munich, Staatsarchiv München ...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Staatsarchiv... -
X-Ray Fluorescence and Relectography Data from Paris, Bibliothèque Nationale ...
XRF (Elio: 40kV, 20 µA, spot measurements of 60s each), and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from BNF Lat9654 from the... -
X-Ray Fluorescence and Reflectography Data from Hamburg, Staats- und Universi...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 to 26 points of 20s each) and reflectography (DinoLite: x50 magnification under vis, NIR and UV light) analysis of manuscripts...